Deye GE-F256 Outdoor Battery Cabinet | Small-Scale C&I ESS Solution | Hybrid Energy Storage System

SKU: S-DeGEF256-US
  • Ultimate Safety: Features a six-dimensional protection system ensuring continued “0” safety accidents and hour-level fire resistance
  • All-in-One Integration: Enables fast, wall-mount-free deployment with a hybrid inverter for versatile PV+ESS(+DG) configurations
  • Stable & Efficient: Powered by long-life LFP batteries (≥8000 cycles) with high-temperature operation and 200% PV over-matching for excellent ROI
  • Intelligent Management: Offers AI-driven energy optimization and seamless scalability supporting up to 10-unit parallel expansion

See the Specs> 

Deye GE-F128 

Deye GE-F256 

$72,030.00$79,999.00 Save $7,969.00
Add to Wishlist

visamasteramerican expressshopify paydiscoverdiners clubapple paygoogle pay
Estimated delivery in 5-7 business days: between and if ordered today.
Description

The GE-F256 system is one part of DEYE GE Series for Small-Scale C&I ESS Solution, offering a compact, small-scale energy storage solution ideal for commercial and industrial (C&I) applications. Designed with advanced technology, these systems ensure high efficiency, safety, and scalability for off-grid energy needs.

Key Features:

  • Ultimate Protection, Continuing "0" safety accidents
    - Six-dimensional safety design, eliminating the risk of fire and explosion
      D1 electrical isolation + D2 physical insulation + D3 active exhaust + D4 directional venting + D5 aerosol suppression + D6 water fire sprinkler
    - High-intensity cabinet, unique patented door latch design, eliminates structural weak points
    - Hour-level fire resistance, prevent heat spread
  • Stable Efficient,  Excellent performance ensures returns
    - Long-life lithium iron phosphate battery, ≥ 8000 cycles
    - High-efficiency thermal management, no derating at 45°C, cell temperature difference ≤6°C
    - 0.63C Max Continuous Charge/Discharge, Fast & Stable Power Supply
  • Highly Integrated,  All-in-one quick deployment
    - Outer cabinet wall preset inverter bracket installation position, no wall bearing concerns, no need to drill
    - Single cabinet can easily deploy PV+BESS, PV+BESS+DG
    - Can be installed side by side or back to back,reducing the footprint
  • Intelligent Management, Flexible adaptation and expansion 
    - Leading rack-level + pack-level + cell-level energy balancing algorithm, non-inductive pack change and cabinet expansion
    - Single cabinet can be configured with a 2/4h ESS system, up to 10 units battery cabinet parallel
    - Integrated energy platform, 24/7 AI smart customization of optimal power usage strategies


Technical Specifications:

Specifications GE-F128 GE-F256
Cell Chemistry LiFePO₄ LiFePO₄
Module Energy 16.08 kWh 16.08 kWh
Module Voltage (V) 51.2 51.2
Module Capacity (Ah) 314 314
Module Qty In Series 8 16
System Voltage (Vdc) 409.6 819.2
System Operating Voltage (Vdc) 320-647.2 640-934.4
System Usable Energy (kWh) 128.61 257.23
Rated DC Power (kW) 64 129
Charge/Discharge Current (A) 200 200
IP Rating IP55 IP55
Weight 1690 kg 2770 kg
Dimensions (W×D×H mm) 998 × 1240 × 2405.5 1300 × 1240 × 2510
Operating Temperature -30°C to 55°C (derating >45°C) -30°C to 55°C (derating >45°C)
Warranty 10 years 10 years


Why Choose GE-F256?

  • Dependability: Long lifecycle (≥8000 cycles at 25±2°C, 0.5P, EOL70%).
  • Versatility: Supports variable installation environments and a wide temperature range.
  • Compliance & Certifications: Fully certified with UN38.3, UL1973, UL9540A, UL9540-DC NFPA855 standards, ensuring global acceptance.

Perfect for small-scale commercial and industrial energy storage applications, the GE-F256 deliver unmatched performance, safety, and scalability. Innovate your energy with the DEYE GE Series!

    HESS Solution (Recommend)

    AC/DC Side Parallel Expansion (Capacity & Power)

    Download

    Datasheet:
    DEYE-ESS-GE-F256_Solution_Brochure_20260313V1.0_NA.pdf
    User Manual:
    DEYE-ESS-GE-F128-BC-4-A1_User-Manual_NAEN_A01.pdf


    ABOUT Deye

    Ningbo Deye Technology Co., Ltd. is a large-scale manufacturing technology enterprise integrating R&D, design, production, sales, and services.Driven by innovation, with a global vision and forward-looking thinking, Deye is devoted to innovation and change following the trend of the industry, producing “intelligent, healthy, energy-saving, and environment-friendly” products.
    Relying on the advantages of China’s vast market and powerful Internet technology resources, Deye has become a brand rooted in China and well-known in the world, an innovator and leader in new energy inverter technology and frequency conversion control core technology, a leading brand in the high-end environmental electrical appliance industry and a famous company in the air-conditioning heat exchanger industry.
    So far, Deye has realized a layout for its diversified development drawing on the dual-core drives of its independent brand and supporting products.

    FAQ

    1. What are the core differences between the GE-F128 and GE-F256?

    GE-F128: Delivers 128.61 kWh nominal energy (approx. 112.5 kWh usable) operating across a voltage range of 320V to 467V DC.   

    GE-F256: Delivers 257.2 kWh nominal energy operating across a high-voltage range of 640V to 934.4V DC.

    2. How scalable are these systems on both the AC and DC sides?

    DC Expansion (Batteries): You can connect up to 10 battery cabinets in parallel on the DC side to scale up total energy capacity.   

    AC Expansion (Inverters): Up to 10 inverter units can be run in parallel on the AC side to scale total power output. 

    3. What safety features are built into the GE cabinet series?

    User and installer discussions emphasize that Deye’s commercial cabinets utilize a multi-layered safety architecture (often referred to as their Six-Dimensional Safety Design):

    Active Protection: Built-in aerosol fire suppression systems, active exhaust, and combustible gas/smoke/temperature sensors.   

    Thermal Isolation: Optimized thermal management designed to keep cell temperature variances to a minimum (≤ 6℃), preventing thermal runaway propagation.

    Structural Durability: High-strength outdoor cabinet ratings (typically IP54/IP65 equivalent protection) with hour-level fire resistance and heavy-duty structural latch designs. 

    4. How do these batteries handle extreme operating environments?

    The systems support operation in demanding climates with no power derating up to 45°C ambient temperature.   They use high-performance LiFePO₄ prismatic cells rated for ≥ 8,000 charge-discharge cycles, making them suitable for heavy daily cycling (arbitrage and peak shaving). 

    5. How does the integrated fire suppression and safety protection system work?

    Deye utilizes a 6-Dimensional Safety Architecture (D1–D6):  

    D1: Electrical Isolation 
    D2: Fire/Smoke Detection & CO Gas Sensors 
    D3: Active Exhaust Ventilation  
    D4: Explosion Venting Ports 
    D5: Built-in Aerosol & Water Fire Interface Suppression  
    D6: Pack-level Thermal Isolation & Hour-Level Fire Resistance 

    6. Are generator sets (DG) supported alongside PV and the battery?

    Yes. The system topology allows for direct PV + BESS + DG (Diesel Generator) integration.The Deye hybrid inverter can automatically signal generator auto-start/stop based on battery State of Charge (SOC) or peak demand thresholds. 

    7. Can the Deye GE-F128 or GE-F256 provide backup power during a grid outage?

    Backup operation depends on the selected inverter or PCS, system controls, and electrical configuration. The battery cabinet alone does not guarantee backup power. Before purchasing, confirm islanding capability, supported backup loads, transfer arrangements, black-start requirements, and the maximum power available during an outage. 

    8. Are Deye GE-F128 and GE-F256 battery cabinets suitable for outdoor installation?

    The relevant Deye configurations list IP55 cabinet protection. However, outdoor suitability also depends on installation instructions, ambient temperature, drainage, access, ventilation, and local electrical and fire codes. Verify the protection rating and environmental limits for the exact model and regional version.